RKI GX-6100 Benzene & VOC Monitor – 0-50 ppm 10.0 eV PID / 0-4,000 ppm 10.6 eV PID – 72-61XZBX-C

No reviews

Price:
Sale price$5,665.00

RKI GX-6100 Benzene & VOC Monitor – 0-50 ppm 10.0 eV PID / 0-4,000 ppm 10.6 eV PID – 72-61XZBX-C

The RKI GX-6100 72-61XZBX-C is a specialized portable gas monitor configured for both benzene-specific and broad-range volatile organic compound (VOC) detection. This configuration combines a 0–50 ppm benzene-specific PID with a 10.0 eV lamp and a separate 0–4,000 ppm VOC PID with a 10.6 eV lamp, giving professionals two distinct PID measurement capabilities in one GX-6100 platform.

Designed for applications where both targeted benzene measurement and general VOC monitoring are required, the 72-61XZBX-C includes a tube holder, box of 10 tubes, rechargeable Li-Ion battery pack, and charger. This combination is well suited for industrial hygiene, petroleum and petrochemical applications, environmental investigations, remediation projects, hazardous material response, and workplace exposure monitoring.

Dual PID Configuration for Benzene & VOCs

A key advantage of the 72-61XZBX-C is its dual PID configuration. The instrument provides dedicated benzene-specific monitoring with a 10.0 eV PID lamp while also providing broad-range VOC monitoring with a separate 10.6 eV PID lamp.

  • Benzene Measurement Range: 0–50 ppm
  • Benzene PID Lamp: 10.0 eV
  • VOC Measurement Range: 0–4,000 ppm
  • VOC PID Lamp: 10.6 eV
  • Sensor Technology: Photoionization Detector (PID)

0–50 ppm Benzene-Specific PID

The benzene-specific channel provides a 0–50 ppm measurement range using a 10.0 eV PID lamp. Combined with the tube-based configuration, this gives users a dedicated measurement capability for applications where benzene is a specific compound of concern.

This targeted benzene capability is especially useful for industrial hygiene and environmental applications involving petroleum products, petrochemical operations, contaminated sites, remediation work, and other environments where benzene exposure may need to be evaluated separately from overall VOC concentrations.

0–4,000 ppm VOC PID

In addition to benzene-specific monitoring, the 72-61XZBX-C incorporates a separate 10.6 eV PID for broad-range VOC detection from 0–4,000 ppm. This provides the ability to screen and monitor volatile organic compounds across a substantially wider concentration range.

Having both PID configurations in the same instrument allows professionals to perform general VOC monitoring while retaining dedicated benzene-specific measurement capability when required.

10.0 eV & 10.6 eV PID Lamps

The two PID channels use different lamp energies for their respective monitoring functions. The benzene-specific configuration uses a 10.0 eV lamp, while the broad-range VOC channel uses a 10.6 eV lamp.

  • 10.0 eV PID: Benzene-specific monitoring from 0–50 ppm
  • 10.6 eV PID: Broad-range VOC monitoring from 0–4,000 ppm

Tube Holder & Box of 10 Tubes Included

The 72-61XZBX-C package includes the tube components specified for its benzene-specific monitoring configuration.

  • Tube holder included
  • Box of 10 tubes included
  • Supports benzene-specific measurements
  • Integrated with the GX-6100 portable monitoring platform

Internal Sample Draw Pump

The GX-6100 is a sample-draw instrument with an internal pump, allowing atmospheric samples to be drawn into the detector from a specific location. Pumped sampling provides flexibility for industrial hygiene surveys, environmental investigations, remediation projects, and other applications where samples need to be collected remotely or from a defined sampling point.

Rechargeable Li-Ion Battery & Charger

This configuration includes a rechargeable Li-Ion battery pack and charger for convenient portable operation. The rechargeable configuration is well suited for professionals performing repeated benzene and VOC measurements in field, industrial, and environmental monitoring applications.

  • Rechargeable Li-Ion battery pack included
  • Charger included
  • Portable configuration for field monitoring
  • Designed for repeated professional measurements

Key Features & Benefits

  • Dual PID configuration for benzene and VOC monitoring
  • 0–50 ppm benzene-specific measurement range
  • 10.0 eV PID lamp for benzene-specific monitoring
  • 0–4,000 ppm broad-range VOC measurement
  • 10.6 eV PID lamp for VOC monitoring
  • Allows targeted benzene and general VOC measurements with one GX-6100
  • Photoionization detector technology
  • Internal sample draw pump
  • Tube holder included
  • Box of 10 tubes included
  • Rechargeable Li-Ion battery pack included
  • Charger included
  • Portable design for professional field monitoring
  • Designed for industrial hygiene and environmental applications

Common Applications

  • Benzene exposure monitoring
  • Broad-range VOC monitoring
  • Industrial hygiene surveys
  • Occupational air monitoring
  • Petroleum and petrochemical applications
  • Environmental site investigations
  • Environmental remediation
  • Contaminated site investigations
  • Hazardous material response
  • Hydrocarbon-related investigations
  • Workplace atmospheric monitoring
  • Field VOC and benzene screening

Dedicated Benzene Detection Plus Broad-Range VOC Monitoring

The RKI GX-6100 72-61XZBX-C provides a specialized solution for applications requiring both targeted benzene measurement and broader VOC monitoring. The 0–50 ppm benzene-specific PID with 10.0 eV lamp provides dedicated benzene measurement capability, while the separate 0–4,000 ppm PID with 10.6 eV lamp expands the instrument's capabilities to general VOC monitoring.

With two distinct PID measurement ranges, a tube holder, box of 10 tubes, rechargeable Li-Ion battery pack, and charger, this GX-6100 configuration provides a versatile portable solution for professional benzene and VOC monitoring.

Free Shipping on All Filtration Media

Our premium carbon and filtration media ships free within the USA. Terms Apply.

Satisfied or Refunded

We have a 30-day return policy, which means you have 30 days after receiving your item to request a return. 

Top-Notch Support

Our customer service team is ready to answer any questions or concerns you may have. Click Here to Contact Us.

Secure Payment

Enjoy peace of mind with our fast, reliable, and secure payment options.

Contact Us For Questions Regarding the RKI GX-6100 Benzene & VOC Monitor – 0-50 ppm 10.0 eV PID / 0-4,000 ppm 10.6 eV PID – 72-61XZBX-C

Ways to Contact Us

Activated Carbon Depot

Activated Carbon Supplier

Email: sales@activatedcarbondepot.com

Phone: 949-229-2587

You may also like

Recently viewed